Overview
Mfr description
1587KIT/62MAX+ FC KIT W/62MAX+ I400
- Includes Fluke 1587 FC 2-in-1 insulation DMM, Fluke i400 Current Clamp, and Fluke 62 Max+ Infrared Thermometer Fluke 1587 FC 2-in-1 Insulation DMM
- Pl/DAR measurements with TrendIt™ graphs
- Memory storage through Fluke Connect Measurements app
- Temperature compensation through Fluke Connect Measurements app
- VFD low-pass filter for accurate motor drive measurements
- Insulation test voltages: 50V, 100V, 250V, 500V, 1,000V
- Insulation test: 0.01 M to 2.0 G
- Auto-discharge of capacitive voltage
- Insulation test smoothing reading
- Frequency/Capacitance/Diode test/Temperature
- Min/Max, AC/DC voltage, DC millivolts, AC/DC milliamps
- Resistance (0.1 M to 50 M)/continuity/auto power off
- Remote probe, test leads, alligator clips, K-type thermocouple, hard case
- 3-year warranty Fluke i400 AC Current Clamp
- Use with Fluke 1587 FC to measure 1A AC to 400A AC
- 1 mA/Amp output guarantees easy reading CAT III 1000 V/CAT IV 600V over voltage rating for added user protection
- Maximum conductor: Ø 32 mm
- 1-year warranty Fluke 62 MAX+ Infrared Thermometer
- Temperature range: -22°F to 1,202°F (-30°C to 650°C)
- Accuracy: ±1.0°C or ±1.0% of reading, whichever is greater
- -10°C to 0°C: ±2.0
- -30°C to -10°C: ±3.0
- Response time: (95%) Fluke 62 MAX+ less than 300 ms (95% of reading)
- Spectral response: 8 to 14 microns
- Emissivity: 0.10 to 1.00
- Optical resolution: 12:1 (calculated at 90% energy)
- Display resolution: 0.1°C (0.2°F)
- Repeatability of readings: ±0.5% of reading or less than ±0.5°C (1°F), whichever is greater
Specifications
- Features & Benefits• Includes Fluke 1587 FC 2-in-1 insulation DMM, Fluke i400 Current Clamp, and Fluke 62 Max+ Infrared Thermometer Fluke 1587 FC 2-in-1 Insulation DMM • Pl/DAR measurements with TrendIt™ graphs • Memory storage through Fluke Connect Measurements app • Temperature compensation through Fluke Connect Measurements app • VFD low-pass filter for accurate motor drive measurements • Insulation test voltages: 50V, 100V, 250V, 500V, 1,000V • Insulation test: 0.01 M to 2.0 G • Auto-discharge of capacitive voltage • Insulation test smoothing reading • Frequency/Capacitance/Diode test/Temperature • Min/Max, AC/DC voltage, DC millivolts, AC/DC milliamps • Resistance (0.1 M to 50 M)/continuity/auto power off • Remote probe, test leads, alligator clips, K-type thermocouple, hard case • 3-year warranty Fluke i400 AC Current Clamp • Use with Fluke 1587 FC to measure 1A AC to 400A AC • 1 mA/Amp output guarantees easy reading CAT III 1000 V/CAT IV 600V over voltage rating for added user protection • Maximum conductor: Ø 32 mm • 1-year warranty Fluke 62 MAX+ Infrared Thermometer • Temperature range: -22°F to 1,202°F (-30°C to 650°C) • Accuracy: ±1.0°C or ±1.0% of reading, whichever is greater • -10°C to 0°C: ±2.0 • -30°C to -10°C: ±3.0 • Response time: (95%) Fluke 62 MAX+ less than 300 ms (95% of reading) • Spectral response: 8 to 14 microns • Emissivity: 0.10 to 1.00 • Optical resolution: 12:1 (calculated at 90% energy) • Display resolution: 0.1°C (0.2°F) • Repeatability of readings: ±0.5% of reading or less than ±0.5°C (1°F), whichever is greater
Compliance & Safety Data
Click on an icon below to learn more about the compliance and safety data